PLC CONTROLS
SIEMENS 195-0011 Controller,Receiver SIEMENS Item Specifics Item: Pneumatic Receiver Controller Type: Dual Input Air Consumption (SCFM): – Application: Used to Control Temperature, Humidity and Pressure of Mechanical Equipment in Commercial Buildings such as Offices, Hospitals, Universities and Schools Authority: – Compensation Start Point: – Depth (In.): 3-1/2 Gauge: No Height (In.): 5-11/16 Includes: Plug-in Air Connectors and Internal Restrictors for Transmitter Inputs Item: Pneumatic Receiver Controller Operating Temp. Range (F): 40 to 120 Pressure (PSI): 22 Op; 30 max. Reset Capability: No Type: Dual Input Width (In.): 6-3/4 Control Type: Input #1 DA, Input #2 RA Output: 0 to 22 Product Description: – Characteristics: – Air Consumption: 60 SCIM Air Input Range (PSI): 3 to 15
|
---|
Honeywell T7047C2007 Electronic T Stat Remote Setpoint Thermistor Element *NEW OLD STOCK*
* Listing shows stock photo.
1420 ohm electronic sensor used in 70 series systems.
I:CNG02T
** IMAGE IS STOCK PHOTO FROM VERIS WEBSITE **
These immersion probe type temperature sensors are both highly accurate and cost effective. Installation could not be easier. The sensor is encased in a corrosion-resistant stainless steel probe for durability, with 1/2″ NPT threads standard.
- Wiring 22AWG; 2-wire:RTD Thermistor, 4-20mA; 3-wire: Voltage output models
- Probe Stainless Steel
- Test Pressure 200psi
APPLICATIONS
- Tanks
- Pipes
- Chillers
- Corrosion resistant stainless steel probe design
I:CNG05T
SIEMENS 172K-10308 BALL VALVE, 2WAY, 3/4″, 6.3CV, PROP, SR -NEW -FREE SHIPPING
2-way 3/4 inch, 6.3 Cv ball valve assembly with chrome-plated brass ball and brass stem, 2-10 V, NC, fail safe actuator, 200 psi close-off, NPT
- 200 psi close-off pressure
- 0.4 to 160 Cv ranges depending on valve size
- 600/WOG/ANSI 250 pressure rating
- Double o-ring stem packing
- Blow-out proof stem for high pressure safety
- Thermal barrier on universal mounting bracket
SHIPPING: FREE UPS
SHIPPING: FREE UPS
A warmer/cooler dial is included on certain models for minor temperature adjustments from the setpoint. An occupancy override button allows the user to request a time-of-day scheduling override when the space is occupied outside of the normal occupied hours schedule. All sensors have DIP switches that enable or disable unit functions.
Depending on the model chosen, the wires connecting the sensor to the controller can be terminated using a screw terminal block or modular jack connection, offering wiring flexibility. All models include a Zone Bus access port for connecting accessories to access the 6-pin modular jack. This feature allows a technician to commission or service the controller via the sensor.
Features:
- Controller configuration switch — allows users to adjust room comfort and to choose occupancy features that match the application and controller
- Occupancy Light-Emitting Diode (LED) indicator — displays the current operating mode of the controller (VMA1200 and VMA1400 Series controllers only)
- Manual override Pushbutton (PB) — overrides time-of-day scheduling when the space is occupied outside of normal occupied hours schedule
SHIPPING: FREE USPS
I:CNG54T
for Use with Cassia™ Energy Management Systems
The Cassia™ Energy Management System (EMS) is comprised of EMS
Thermostats, Door Sensors, Motion Sensors, and Ethernet Coordinators (ECs).
The EMS reduces energy costs by minimizing HVAC usage when a guest room
is unrented or vacant. The EMS allows continuous monitoring of all online
devices within the property.
The EMS Door Sensor consists of a base (containing the Zigbee radio,
magnetic sensor, and battery) and separate magnet. The door sensor uses a
CR-2 lithium battery.
Power 3V CR-2 Lithium Battery
Temperature range -4° F to 140°F (-20°C to +60°C)
Communications 2.4 GHz, 16 channel spread spectrum radio frequency
DIMENSIONS
Component Dimensions
Magnet 2.5 x 0.32 x 0.39 in. (63.5 x 8.1 x 9.9 mm)
Door Sensor 2.5 x 0.81 x 0.86 in. (63.5 x 20.5 x 21.8 mm)
STANDARDS
The Door Sensor complies with the following Standards:
Table 1: U.S. FCC Regulations
Standards/Regulations Title
FCC Part 15 Class B Digital Device for Home or Office Us
SHIPPING: FREE USPS
I:CNG54T
Temperature sensors are available in thin-film nickel, thin-film platinum, and silicon. The elements are powered with 14 to 30 VDC or 20 to 30 VAC and feature a user-selectable humidity output of 0 to 10 VDC or 0 to 5 VDC.
Features:
- TRUERH circuitry and calibration techniques for which patent protection is pending
- All-Polymer humidity sensor patented sensing element provides accurate and reliable humidity sensing
- tested and calibrated with equipment certified to be in compliance with National Institute of Standards and Technology (NIST) guidelines
- ±2% RH accurate model includes test and calibration equipment certificate of calibration conformance
- humidity and temperature sensors in one unit eliminates the need for separate sensors and reduces installation costs
- user-selectable output voltage range allows choice of standard voltage outputs for use with systems in service or new systems
SHIPPING: FREE USPS
I:CNG54T
Temperature Sensors, NS Network Sensors Series
Item# NS-BTN7001-0 – 3X4.5.T.Pj; Network Rm 3″X4.5″ Temp Sensor Ms/Tp. Phone Jck.
- BACnet® Master‑Slave/Token‑Passing (MS/TP) Protocol Communication — Provides Compatibility with Metasys System Field Controllers and Facility Explorer Programmable Controllers in a Proven Communication Network
- Backlit LCD Available on Some Models — Provides Real‑Time Status of the Environment with Backlighting Activated During User Interaction
- Simple Temperature Setpoint Adjustment Available on Some Models — Enables You to Change the Setpoint with the Turn of a Dial
- Onboard PIR Occupancy Sensor Available on Some Models — Maximizes up to 30% Energy Savings in High‑Energy Usage Environments, and Facilitates Trending of Floor Space Usage
- Temporary Occupancy Available on Some Models — Provides a Timed Override Command, Which Temporarily Initiates an Alternate Mode
- Field Selectable Default Display Setting on Some Models — Allows You to Toggle between Temperature and RH on the Display, and Set the Desired Default for Continuous Viewing
- Fahrenheit/Celsius (F/C) Button Available on Some Models — Toggles the Display Temperature between Degrees Celsius and Degrees Fahrenheit
The majority of NS Series Network Zone Sensors monitor room temperature; however, options are available to also monitor zone humidity, carbon dioxide (CO2), local temperature setpoint adjustments, and other variables. This data is transmitted to a controller on the Sensor Actuator (SA) Bus.
Some models of NS Series Network Zone Sensors include an onboard passive infrared (PIR) occupancy sensor that detects motion to determine if a space is occupied. This feature maximizes up to 30% energy savings in high‑energy usage environments such as schools, dormitories, offices, hospitals, and hotels by adjusting the temperature of the space based on the occupancy status. In addition, the PIR occupancy sensor facilitates trending of floor space usage in these environments.
The NS Series Network Zone Sensors include models with a temperature setpoint dial and LCD that allows occupants to view the zone temperature, Relative Humidity (RH), and view and adjust the zone temperature setpoint. Some temperature and humidity models include a push button to toggle between temperature and RH on the display. These models also have the capability to set the desired default display to either temperature or RH.
A fan mode push button is included to set the desired fan speed (AUTO‑OFF‑low‑medium‑high). An occupancy override function allows the user to signal to the controller that the zone is occupied to override the scheduled mode. Some models have DIP switches to set a unique address for applications that require multiple sensors.
For communication wiring flexibility, the wires connecting the network zone sensor to a controller can be terminated using a modular jack or screw terminals. Note: Mixing of phone jack and screw terminal devices on the same SA bus segment must be avoided.
Each network sensor includes an SA Bus access port to allow accessories to access the SA Bus. This plug allows accessories to service or commission the connected controller or gain access to any other controller on the same Field Controller (FC) Bus.
The NS Series Network Zone Sensor offering includes models that can be surface mounted, vertical wallbox mounted, or flush mounted to meet the requirements of the specific application. Some NS Series Sensor models are designed to assist with the California Energy Code (Title 24). Select models offer stylish black enclosures to suit specific architectural and interior design needs.
The NS Series Network Discharge Air Sensors monitor the duct temperature, typically at the discharge of the VAV box, and transmit this data to a local controller on the SA Bus using the 10 ft (305 cm) wiring lead included with the unit. The 10 ft (305 cm) wiring lead consists of four 22 AWG (0.6 mm) trade size color‑coded wires encased in a plenum‑rated jacket. Each of the wires is stripped and tinned for easy connection to the SA Bus screw terminal block.
The NS Series Network Discharge Air Sensors are available with either a 4‑ or 8‑in. (102 or 203 mm) temperature probe. All models include DIP switches for applications requiring multiple discharge air sensors, each with a unique DIP switch address
Specifications
SHIPPING: FREE USPS
I:CNG54T
Johnson Controls Temperature Sensors, NS Network Sensors Series
- BACnet® Master‑Slave/Token‑Passing (MS/TP) Protocol Communication — Provides Compatibility with Metasys System Field Controllers and Facility Explorer Programmable Controllers in a Proven Communication Network
- Backlit LCD Available on Some Models — Provides Real‑Time Status of the Environment with Backlighting Activated During User Interaction
- Simple Temperature Setpoint Adjustment Available on Some Models — Enables You to Change the Setpoint with the Turn of a Dial
- Onboard PIR Occupancy Sensor Available on Some Models — Maximizes up to 30% Energy Savings in High‑Energy Usage Environments, and Facilitates Trending of Floor Space Usage
- Temporary Occupancy Available on Some Models — Provides a Timed Override Command, Which Temporarily Initiates an Alternate Mode
- Field Selectable Default Display Setting on Some Models — Allows You to Toggle between Temperature and RH on the Display, and Set the Desired Default for Continuous Viewing
- Fahrenheit/Celsius (F/C) Button Available on Some Models — Toggles the Display Temperature between Degrees Celsius and Degrees Fahrenheit
The majority of NS Series Network Zone Sensors monitor room temperature; however, options are available to also monitor zone humidity, carbon dioxide (CO2), local temperature setpoint adjustments, and other variables. This data is transmitted to a controller on the Sensor Actuator (SA) Bus.
Some models of NS Series Network Zone Sensors include an onboard passive infrared (PIR) occupancy sensor that detects motion to determine if a space is occupied. This feature maximizes up to 30% energy savings in high‑energy usage environments such as schools, dormitories, offices, hospitals, and hotels by adjusting the temperature of the space based on the occupancy status. In addition, the PIR occupancy sensor facilitates trending of floor space usage in these environments.
The NS Series Network Zone Sensors include models with a temperature setpoint dial and LCD that allows occupants to view the zone temperature, Relative Humidity (RH), and view and adjust the zone temperature setpoint. Some temperature and humidity models include a push button to toggle between temperature and RH on the display. These models also have the capability to set the desired default display to either temperature or RH.
A fan mode push button is included to set the desired fan speed (AUTO‑OFF‑low‑medium‑high). An occupancy override function allows the user to signal to the controller that the zone is occupied to override the scheduled mode. Some models have DIP switches to set a unique address for applications that require multiple sensors.
For communication wiring flexibility, the wires connecting the network zone sensor to a controller can be terminated using a modular jack or screw terminals. Note: Mixing of phone jack and screw terminal devices on the same SA bus segment must be avoided.
Each network sensor includes an SA Bus access port to allow accessories to access the SA Bus. This plug allows accessories to service or commission the connected controller or gain access to any other controller on the same Field Controller (FC) Bus.
The NS Series Network Zone Sensor offering includes models that can be surface mounted, vertical wallbox mounted, or flush mounted to meet the requirements of the specific application. Some NS Series Sensor models are designed to assist with the California Energy Code (Title 24). Select models offer stylish black enclosures to suit specific architectural and interior design needs.
The NS Series Network Discharge Air Sensors monitor the duct temperature, typically at the discharge of the VAV box, and transmit this data to a local controller on the SA Bus using the 10 ft (305 cm) wiring lead included with the unit. The 10 ft (305 cm) wiring lead consists of four 22 AWG (0.6 mm) trade size color‑coded wires encased in a plenum‑rated jacket. Each of the wires is stripped and tinned for easy connection to the SA Bus screw terminal block.
The NS Series Network Discharge Air Sensors are available with either a 4‑ or 8‑in. (102 or 203 mm) temperature probe. All models include DIP switches for applications requiring multiple discharge air sensors, each with a unique DIP switch address
Specifications
SHIPPING: FREE USPS
I:CNG54T
Features and Applications
- Low cost with high reliability
- Available in pressure ranges from 0/0.25”WC up to 0/15PSI, including bi-directional
- Output stability of 0.5% FSO
- Perfect for a variety of air and inert gas applications such as duct static, VAV and fan control
- Easy wiring via a pluggable screw terminal block
- Pressure range calibrated to customer’s specific requirement
- Able to handle high overpressure
- Internally conditioned allowing it to automatically accept unregulated 12-24 VDC or 24 VAC power
- Dual die sensor allows for the best temperature correction
- Each unit is individually temperature compensated
Specifications
Accuracy*: | <+/-1.0% FSO |
Stability: | +/-0.5% FSO/yr |
Thermal Effects: | +/-0.075%/°C |
Overpressure: | 1-10”WC = 100”WC 11-20”WC = 10x rated pressure 21-30”WC = 5x rated pressure Over 30”WC = 45 PSI |
FSO Pressure Range: | 0/0.25”WC up to 0/15PSI (bi-directional ranges available) |
Compensated Range: | 10° to 50°C |
Media: | Non-corrosive, non-ionic gases |
Operating Humidity: | 90% RH non-condensing |
Operating Temp: | -25° to 70°C |
Input Supply**: | 12-24 VDC/24VAC** |
Supply Current: | |
Load Resistance: | 2KΩ minimum on voltage out, 250Ωmaximum loop resistance on 4-20mA output (500Ω max loop resistance available upon request**) |
Output Signal: | 1-5VDC, 1-6VDC, 1-10VDC** or 4-20mA*** (call for custom outputs) |
Circuit Protection: | Output limited and reverse voltage protected |
Electrical Connections: | Pluggable Screw Terminal Block |
Pressure Connections: | Barbed fitting for 1/8” ID tubing |
Enclosure: | Impact resistant ABS plastic |
Dimensions: | Approx. 3.5” x 2.7” x 1.4” (8.7cm x 6.8cm x 3.5cm) |
* Includes non-linearity hysteresis and non-repeatability at a fixed temperature
** An input of 18-24VDC/AC is required to drive a 500Ω load; the same input is also required for a 1-10VDC output
*** 3-wire 4-20mA
- Room Temperature Sensor
- Digital P1
- No HMI
- No Logo
- Tool Port
- RJ-11 Connection
- For Siemens TEC Controllers Only
Product Attributes
- 1.00 lbs
- United States of America
- 9032100030
- DIGITAL P1
- 10K THERMISTOR
SHIPPING: FREE USPS
I:CNG54T
Specifications
Item Number | QAA2230.FWNC |
Brand | Siemens |
Element Type | 10K Type II |
Sensor Configuration | Room |
Sensor | Temperature |
SHIPPING: FREE USPS
I:CNG54T
Details for M9116-AGC-2
ELECTRIC MOTOR ACTUATOR; 140 IN-LB/16NM; 24 VAC/VDC; ON/OFF-FLOATING; 80 SEC; 2 AUX SWITCHES
Specifications
Item Number | M9116-AGC-2 |
Brand | Johnson Controls |
Actuator Type | Damper |
Control Input | Floating |
End Switch | No |
Housing | NEMA 2 |
Spring Return | Non-Spring Return |
Torque | 140 in-lb |
Voltage | 24V |
SHIPPING: FREE UPS
I:CNG54T
Product Features
SHIPPING: FREE UPS
I:CNG54T
SHIPPING: FREE USPS
I:CNG54T
Setra’s Model 267 and 267MR pressure transducers sense gauge (static) or differential pressure in air pressure ranges as low as 0.1”WC Full Scale up to 100”WC.
The Model 267 gauge pressure transducer is offered in a high level voltage or 4 to 20 mA output and is available with a static pressure probe for installation directly onto the duct. The 0.25” diameter pressure probe is made of sturdy extruded aluminum and is designed with baffles to prevent velocity pressure errors. This unit is also available with an LCD display.
The 267MR multi-range transducer offers 6 field selectable pressure ranges (bidirectional and unidirectional), and field configurable outputs of 0 to 5 VDC, 0 to 10 VDC, and 4 to 20 mA. With the flip of a switch the user can field calibrate the unit and be assured of optimum performance.
- Multi-Range Capability
- 6 Field Selectable Ranges via Dip Switches
- Field Selectable 0 to 5 VDC or 0 to 10 VDC Output
- NEMA 4/IP65 Rated Housing
- Optional Accuracies as High as 0.25% FS
- Optional LCD Display
- 24 VAC or 24 VDC Excitation
- Integral Static Probe
Technical Specifications | |
---|---|
Model: | Model 267 |
Ranges: | {R25} 0 to 0.25 or +/- 0.25 |
Units: | {W} in WC |
Type: | {D} Unidirectional |
Output: | {2E} 0-10 VDC |
Fitting Type: | 1/4″ NPT F, Brass, Optional Fitting |
Electrical Termination: | {A1} 1/2″ Conduit Opening |
Accuracy: | {H} +/- 0.5% FS – with Cal. Cert |
Display: | {D} LCD Display |
Metasys (Johnson Controls) AS-VAVDPT1-1 Controller -New Old Stock -Free Shipping
Condition: New old stock. Sealed in factory sealed box. Box a little worn. See pics.
Shipped: Free USPS Parcel select ground
Inv: cng82s
SPECIFICATIONS
Application Zone | : | Living Space |
Application | : | Wall |
Brand | : | Veris |
CO2 Measurement Accuracy | : | ±30 ppm ±2% of measured value |
CO2 Measurement Range | : | 0 – 2000 ppm | 0 – 5000 ppm |
CO2 Measurement Repeatability | : | ±20 ppm ±1% of measured value |
CO2 Measurement Resolution | : | 1 ppm |
CO2 Sensor Type | : | NDIR |
Color | : | Cloud White |
Dimension Depth | : | 1.2″ (30 mm) |
Dimension Height | : | 4.8″ (122 mm) |
Dimension Width | : | 3.5″ (89 mm) |
Display Resolution | : | 2 Rows x 8 Characters |
Display Size | : | 1.2″ x 0.6″ (30,5 mm x 14 mm) |
Display Type | : | LCD |
Electrical Wiring Size | : | 24 – 18 AWG (0.22 – 0.75 mm²) |
Enclosure Material | : | ABS Plastic |
Humidity Calibration Certificate | : | None |
Measurement Type | : | CO2 |
Mounting | : | Wall |
Operating Humidity | : | 0 – 95% RH, non-condensing |
Operating Temperature | : | 32 – 122 °F (0 – 50 °C) |
Output Specifications | : | 4 – 20 mA | 0 – 5 V | 0 – 10 V |
Outputs | : | Analog output |
Override | : | No |
Product Certification | : | CE |
Product Type | : | Sensor |
Range | : | CWL |
Response Time | : | CO2: <60 seconds for 90% step change |
Setpoint | : | No |
Supply Voltage AC Nominal | : | 24 VAC |
Supply Voltage DC Nominal | : | 20 – 30 VDC |
Temperature Calibration Certificate | : | None |
Temperature Sensor Type | : | None |
Warranty | : | 5 years |
FEATURES
CWL carbon dioxide (CO2) sensors maximize energy savings, while helping optimize ventilation. These sensors allow ventilation systems to be controlled by the amount of CO2 present in a space. The CWL series detect fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for the space at a given time saving energy and increasing tenant comfort.
- Microprocessor based design increases accuracy and reduces installation time
- Self-calibrating – innovative self-calibration algorithm easy to maintain
- Non-dispersive infrared technology (NDIR) repeatable to +/-20 ppm +/-1% of measured value high accuracy measurement
- Snap-on faceplate no screws required, making installation and service easy
- Field-selectable outputs for operation flexibility
- Integrated probe – integrated transducer and probe eliminates the need to install a separate pick-up tube
- Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) US Patent 5,844,138 HS sensor
SIEMENS Landis & Staefa NRK16/A Remote Control Application Controller.
Condition: New old stock. Never installed. Has storage blemishes. See pics for details. Ask questions before purchasing.
Shipping: Free shipping – UPS
Item specifics
Power Source: Corded Electric
Item specifics
Item specifics
Item specifics
Setra 2301100PD2F2DB Differential Pressure Transducer 0-100 PSID .05-5.05 VDC.
These are high level output, low differential pressure transducer designed for wet to wet differential pressure measurements of liquids or gases. A fast-response capacitance sensor and signal conditioned electronic circuitry provide a highly accurate, linear analog output proportional to pressure. Both unidirectional and bidirectional pressure ranges are available for applications with line pressure up to 250 psig. All parts exposed to the pressure media are stainless steel and elastomer seals. The unit has a NEMA 4/IP65 rated package to withstand environmental effects.
They can be supplied with an optional 3-valve manifold assembly for ease of installation and assembly. The 3-valve manifold is a machined brass body requiring no internal pipe connections, thereby eliminating the risk of internal leaks. The manifold’s rugged, yet compact, construction requires minimum space for installation and use. The bleed ports allow for total elimination of air in the line and pressure cavities. If the unit is ordered with the 3-valve manifold, the system is shipped completely assembled and ready for a wall or piping mounting.
Condition: New unit. Worn box. Please see pics for details. Ask questions before purchasing.
Item specifics
TM-2161-0005 JOHNSON CONTROLS SENSOR
Description
UPC | ‘66201104354’ |
---|---|
Manufacturer | Johnson Controls |
Part Number | TM-2161-0005 |
Short Description | TM21610005 |
* IMAGE IS STOCK PHOTO AND MAY NOT BE EXACT *
TAC Xenta 101-VF-24 3-Speed Fan Coil Controller. Controller new old stock. Box has minor storage scuffs.
TC sensors are ceiling-mounted in an unobtrusive housing. The easy-to-install units are ideal for office environments, as well as museums, galleries, or any other open setting. These sensors are highly accurate, reliable, and come with an extended five-year warranty.
APPLICATIONS
- Hospitals and operating rooms, pharmaceutical labs
- Clean rooms
- Food processing plants
- Environmental testing facilities and other institutional applications
- Ceiling mount probe for more accurate readings…ideal for open office environments
- Recessed press-fit sensor virtually “disappears”…great for museums and galleries
- Wiring 22AWG; 2-wire:RTD Thermistor, 4-20mA; 3-wire: Voltage output models
- Housing White ABS Plastic (For Black, consult factory)
SHIPPING: FREE USPS
I:CNG110S